{"product_id":"thermal-overload-reset-button-for-gentilin-c330-compressor","title":"Thermal Overload Reset Button for Gentilin C330 Compressor –","description":"\u003ch2 data-section-id=\"a4nwtr\" data-start=\"97\" data-end=\"162\"\u003eThermal Overload Reset Button for Gentilin C330 Compressor\u003c\/h2\u003e\n\u003cp data-start=\"164\" data-end=\"371\"\u003eProtect your compressor motor from overheating and electrical overload with this replacement thermal overload reset circuit breaker switch designed for use on the \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eGentilin C330 Compressor\u003c\/span\u003e\u003c\/span\u003e range.\u003c\/p\u003e\n\u003cp data-start=\"373\" data-end=\"715\"\u003eThe Gentilin C330 series is known for continuous-duty performance, oil-free operation and high airflow output using patented AXXER motion technology. These compressors are built for demanding plastering, rendering and spraying applications including hopper guns, thin coat render and tanking slurry work. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"717\" data-end=\"1116\"\u003eWhen the compressor experiences a power overload, overheating event or short circuit, the built-in thermal restore system automatically cuts power to protect the motor. The reset button allows the user to safely restore operation once the unit has cooled down. Gentilin manuals describe this as a “thermal restore” safety device fitted to the electrical system. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"1iz91iu\" data-start=\"1118\" data-end=\"1134\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"1136\" data-end=\"1575\"\u003e\n\u003cli data-section-id=\"all6zq\" data-start=\"1136\" data-end=\"1197\"\u003eReplacement thermal overload reset switch \/ circuit breaker\u003c\/li\u003e\n\u003cli data-section-id=\"ix98xt\" data-start=\"1198\" data-end=\"1238\"\u003eDesigned for Gentilin C330 compressors\u003c\/li\u003e\n\u003cli data-section-id=\"1glyazw\" data-start=\"1239\" data-end=\"1293\"\u003eProtects against overheating and electrical overload\u003c\/li\u003e\n\u003cli data-section-id=\"15tvel3\" data-start=\"1294\" data-end=\"1330\"\u003ePush-button manual reset operation\u003c\/li\u003e\n\u003cli data-section-id=\"77u99e\" data-start=\"1331\" data-end=\"1391\"\u003eHelps prevent motor damage during continuous spraying work\u003c\/li\u003e\n\u003cli data-section-id=\"obwkmq\" data-start=\"1392\" data-end=\"1440\"\u003eIdeal for plastering and rendering compressors\u003c\/li\u003e\n\u003cli data-section-id=\"1bg4yv1\" data-start=\"1441\" data-end=\"1496\"\u003eSuitable for oil-free direct drive compressor systems\u003c\/li\u003e\n\u003cli data-section-id=\"gchr8q\" data-start=\"1497\" data-end=\"1527\"\u003eCompact panel-mounted design\u003c\/li\u003e\n\u003cli data-section-id=\"ube20e\" data-start=\"1528\" data-end=\"1575\"\u003eReliable protection for site and workshop use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"w2eo3m\" data-start=\"1577\" data-end=\"1596\"\u003eCompatible With\u003c\/h3\u003e\n\u003cul data-start=\"1598\" data-end=\"1745\"\u003e\n\u003cli data-section-id=\"16yil0t\" data-start=\"1598\" data-end=\"1616\"\u003eGentilin C330\/03\u003c\/li\u003e\n\u003cli data-section-id=\"16yikyw\" data-start=\"1617\" data-end=\"1635\"\u003eGentilin C330\/24\u003c\/li\u003e\n\u003cli data-section-id=\"1tsv1aa\" data-start=\"1636\" data-end=\"1660\"\u003eGentilin CSK330 series\u003c\/li\u003e\n\u003cli data-section-id=\"3kjmgc\" data-start=\"1661\" data-end=\"1745\"\u003eOther compatible oil-free twin cylinder compressors using thermal reset protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1ijlq9b\" data-start=\"1747\" data-end=\"1796\"\u003eCommon Symptoms of a Failed Thermal Protector\u003c\/h3\u003e\n\u003cul data-start=\"1798\" data-end=\"1959\"\u003e\n\u003cli data-section-id=\"yk0ku8\" data-start=\"1798\" data-end=\"1836\"\u003eCompressor suddenly stops during use\u003c\/li\u003e\n\u003cli data-section-id=\"5c3d7z\" data-start=\"1837\" data-end=\"1866\"\u003eCompressor will not restart\u003c\/li\u003e\n\u003cli data-section-id=\"1n3spbo\" data-start=\"1867\" data-end=\"1903\"\u003eReset button will not stay engaged\u003c\/li\u003e\n\u003cli data-section-id=\"fc8z7v\" data-start=\"1904\" data-end=\"1929\"\u003eIntermittent power loss\u003c\/li\u003e\n\u003cli data-section-id=\"zyximh\" data-start=\"1930\" data-end=\"1959\"\u003eTrips repeatedly under load\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"o8of7d\" data-start=\"1961\" data-end=\"1986\"\u003eWhy This Part Matters\u003c\/h3\u003e\n\u003cp data-start=\"1988\" data-end=\"2314\"\u003eGentilin compressors are designed for heavy continuous-duty operation with no thermal stops under normal conditions. However, in extreme working conditions or electrical faults, the thermal overload protection system prevents permanent motor damage by shutting the compressor down safely. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"2316\" data-end=\"2418\"\u003eReplacing a faulty thermal restore breaker can restore reliable operation and reduce downtime on site.\u003c\/p\u003e","brand":"gentilin","offers":[{"title":"Default Title","offer_id":53599395774807,"sku":"cos gent","price":9.99,"currency_code":"GBP","in_stock":true}],"url":"https:\/\/pftplasteringmachines.com\/products\/thermal-overload-reset-button-for-gentilin-c330-compressor","provider":"PFT Wales","version":"1.0","type":"link"}